161-193 uF MFD 125 VAC ±20% 50/60 Hz CD60 Round Motor Well Pump Start Capacitor - Fits Air Conditioners, Heat Pumps - 2 Pack161 193 uf MFD 125 VAC 20% 50 60 Hz CD60 Round Motor Well Pump Start Capacitor Pack of 2 Key Features Quantity: 2 Capacitors Type: CD60 Motor Start Capacitor Capacitance: 161 193 Microfarad (uf MFD) Voltage Rating: 125 Volts AC Frequency: 50 60 Hz Capacitance Tolerance: 20% Construction: Round, moisture and oil resistant phenolic resin case Terminals: 1 4 inch male quick connect Certification: UL Recognized Replaces Cross Reference Part Numbers This
161-193 uf/MFD 125 VAC ±20% 50/60 Hz CD60 Round Motor Well Pump Start Capacitor - Pack of 2
Key Features
- Quantity: 2 Capacitors
- Type: CD60 Motor Start Capacitor
- Capacitance: 161-193 Microfarad (uf/MFD)
- Voltage Rating: 125 Volts AC
- Frequency: 50/60 Hz
- Capacitance Tolerance: ±20%
- Construction: Round, moisture and oil-resistant phenolic resin case
- Terminals: 1/4 inch male quick-connect
- Certification: UL Recognized
Replaces / Cross-Reference Part Numbers
- This capacitor replaces any start capacitor with matching capacitance (161-193 MFD) and voltage (125 VAC) ratings. The voltage rating must be equal to or greater than the original capacitor.
Compatibility & Fitment
- Designed for single-phase AC motor start-up applications.
- Compatible with 110V and 220V motors.
- Commonly used in:
- Well pumps
- Pool pumps (including Hayward Super Pump and Max Flo 0.75, 1.0, 1.5 HP models)
- HVAC systems
- Central air conditioners
- Heat pumps
- Condenser fan motors
- Compressors
When to Replace
- Motor hums but does not start or turn.
- Motor requires manual assistance to start.
- Breaker trips repeatedly during motor startup.
- Capacitor case is visibly swollen, bulging, or leaking fluid.
Installation Tips
- Disconnect all electrical power to the unit before servicing.
- Safely discharge the existing capacitor to avoid electrical shock.
- Verify that the new capacitor's MFD and voltage ratings match the component being replaced.
- Note the wire placement on the old capacitor before disconnecting.
- Ensure a secure connection to the terminals.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]