USEPA Method 6 (Add-on) Set --- S-44Meets or exceeds the following methods laws requirements: US EPA Method 6: Section 6. 1. 1 (Sampling Train) but excluding the following: Section 6. 1. 1. 2 (Bubbler and Impingers) Section 6. 1. 1. 3 (Glass Wool) Section 6. 1. 1. 4 (Stopcock Grease) Section 6. 1. 1. 6 (Drying Tube) Section 6. 1. 2 (Barometer) Section 6. 1. 3 (Vacuum Gauge and Rotameter) Product Description Start isokinetic sampling (smoke stack testing) using US EPA Method 6 (Sulfur
Meets or exceeds the following methods/laws/requirements:
US EPA Method 6:
Section 6.1.1 (Sampling Train) but excluding the following:
- Section 6.1.1.2 (Bubbler and Impingers)
- Section 6.1.1.3 (Glass Wool)
- Section 6.1.1.4 (Stopcock Grease)
- Section 6.1.1.6 (Drying Tube)
Section 6.1.2 (Barometer)
Section 6.1.3 (Vacuum Gauge and Rotameter)
Product Description
Start isokinetic sampling (smoke-stack testing) using US EPA Method 6 (Sulfur Dioxide) upon unpacking. This sampling method is used to measure Sulfur Dioxide (SO2) containing in the flue gas emitted by stationary sources of air pollution.
This add-on set uses Aer Sampling’s Standard Configuration where the full-length heating box—MKORTM Heater Box (Hot Box) and Box Extender (Riser Box) and the Impinger Box (Cold Box) is hung onto a monorail and move in or out the porthole of the chimney/stack, while traversing the smoke-stack.
Requires the USEPA Method 5 Basic Set (which uses Aer Sampling’s Standard Configuration) to use this add-on set.
N.A.
Product Specifications
Minimum porthole inside diameter needed: ~4 in. (10 cm)
-----
Click on the links in the BOM tables below to view the specifications of individual components of this product.
Other Information
All our products come with a one-year warranty against manufacturing defects and one-month technical support for free. Please refer to our Frequently Asked Questions (FAQs) page for more details.
-----
Information presented here is subjected to Aer Sampling Group's terms and conditions.
In case of discrepancy between English version and the non-English version, the English version shall prevail.
Doc ID: AERHQWW-s-44-en
Last revised (Excluding prices): 0; 03.02.21
Obsolete Catalog ID: -
-----
Bill of Materials (BOM)
What does this product contain? (r2):
The following items are included. Click the Catalog ID below to view individual components of this product.
| S/N | Catalog ID | Quantity | Item Name |
| 1 | K-168 | x1 | Filter Holder, 2", U Type Glass, Kit [EACH] |
| 2 | PN-394 | x1 | Filters, Glass Fiber, Round 47mm [EACH] |
| 3 | K-155 | x1 | Greenburg-Smith Impinger Kit [EACH] |
What does this product need to work? (r2):
Items not included in this set/kit but are needed to make this set/kit works. We assume you already have the items below
| S/N | Catalog ID | Quantity | Item Name |
| 1 |
S-28 S-48 |
x1 | USEPA Method 5 Basic Set [EACH] |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy